Current Transformers (DC Immune)

Applications

  • Electronic watthour meters with DC current tolerance (as defined in IEC 62053 -21, -23)

Features

  • Low cost
  • More than 10 standard size
  • Terminal: ready for PCB mounting or wires with plastic coat
Download Datasheet

Specifications

  • Construction:
    epoxy encapsulated housing
  • Highest voltage for equipment:
    720V AC
  • Insulation resistance:
    1000MΩ @ 500V DC
  • Frequency range:
    50Hz / 60Hz
  • Operating temperature:
    -40℃ to +70℃
  • Accuracy class:
    class 0.1,0.2 (as defined in IEC 61869-2)
  • RoHS compliant
  • CE approved

Product Overview

YuanXing Electronics has developed a range of specially designed dc immune current transform

r, which are used by B2B manufacturers of Electronic Watt Hour Meters. The design of these products is in accordance with the IEC 62053-21 and IEC 62053-23 Industry Standards to ensure that they have a high level of accuracy (class 0.1 and class 0.2) when subjected to DC Current Components, thereby preventing core saturation.

The dc immune current transformer is constructed with a high strength epoxy encapsulation and possess an isolation resistance of 1000 MΩ when tested at 500 Volts DC. They can be operated at frequencies in the range of 50/60 Hz and have a temperature operating range from -40°C to +70°CDe­grees Celsius. Therefore, they provide optimal reliability of operation under a variety of grid conditions. The “DC Immune Current Transformer” series can be supplied in more than ten different sizes for mounting on printed circuit boards (PCBs) or via wire leads. The DC immune current transformer series provides the stability necessary to operate effectively in today’s energy metering environments.

Typical Products

Image Part Number Rated Input (A) Turn Ratio Frequency (Hz) Secondary Burden (Ω) Accuracy Class Dimensions (mm) PDF
Image TA1111 5~30 1000:1
2000:1
2500:1
50 to 400 ≤200 0.1
0.2
0.5
ID-L-W-H 7.0-22.0-18.0-23.0
Image TA1311 5~80 1000:1
2000:1
2500:1
50 to 400 ≤800 0.1
0.2
0.5
ID-L-W-H 7.0-22.0-18.0-23.0
Image Part Number Rated Input (A) Turn Ratio Frequency (Hz) Secondary Burden (Ω) Accuracy Class Dimensions (mm) PDF
Image2 CTT0150 5-150 1:1000
1:2000
1:3000
1:5000
50 to 400 50-400 0.1
0.2
15-58-23-45

    Let’s Build Reliable Engineering Together

    By clicking "Request a Quote", you agree to our Privacy Policy.

    Thank you!

    Your request has been successfully submitted.

    Frequently Asked Questions

    Honeywell needed a stable and highly accurate way to measure current fluctuations in large commercial buildings. Existing sensors often produced noise and drifted over time, creating errors in smart energy dashboards

    Honeywell needed a stable and highly accurate way to measure current fluctuations in large commercial buildings. Existing sensors often produced noise and drifted over time, creating errors in smart energy dashboards

    Honeywell needed a stable and highly accurate way to measure current fluctuations in large commercial buildings. Existing sensors often produced noise and drifted over time, creating errors in smart energy dashboards

    Honeywell needed a stable and highly accurate way to measure current fluctuations in large commercial buildings. Existing sensors often produced noise and drifted over time, creating errors in smart energy dashboards

    Honeywell needed a stable and highly accurate way to measure current fluctuations in large commercial buildings. Existing sensors often produced noise and drifted over time, creating errors in smart energy dashboards